Datalog with HDS: how to?

First you need to download HDS and to install it. After you will need to install drivers for J2534 tool you want to use (it can be Tatrix Openport 2.0, Chipsoft Lite or Mid or any other tool).

You can download drivers here: Tatrix Openport 2.0, Chipsoft Lite or Mid

Than you need to press “Settings” and choose you J2534 tool

After you need to connect to your car (as example I will show on Accord CU2 )

The pictures below marked the categories that you need to choose.

Next you will see a menu with settings. To record all parameters, we use the trigger type – manual. Recording time from 30 sec to 3 min (30 sec is enough to accelerate from 2000 to redline). Start point from 0 sec.

But the recording speed in this mode is low, so it can be used only for understand the overall picture. For car tuning it is better to use a high-speed recording mode, up to 10 parameters. It’s on the right side of the settings menu.

Press the camera icon to start logging

After log recording will finish you can find log file here: C:\Teradyne\HDS\Stored Files\Automotive\Snapshot\

Reflash.Club | Facebook